Send haptic (vibration) sequences¶
Periods are in milliseconds, clamped to 10–2550 in 10 ms steps. Values are stored as period // 10 on the wire.
The list alternates on and off durations. The example above vibrates for 1 s, pauses 300 ms, then vibrates 200 ms.
Limits¶
- At most 18 period values (up to 9 on/off pairs). Longer lists are truncated.
- Requires an active BLE connection (
await tap.run()first).